1.1 |
Input Voltage |
230V ±10% AC, 50Hz, single phase / 24DC |
1.2 |
Output Voltage * |
0 to 10/20/30/40/50/60/70/80/90/100kV DC |
1.3 |
Output Current * |
0 to 6 mA |
1.4 |
Polarity* |
Available with either positive, negative, or reversible polarity with respect to chassis ground. |
1.5 |
Line Regulation |
< 0.05 % for 10% variation in input voltage |
1.6 |
Load Regulation |
< 0.05% for 10 to 100% load variation |
1.7 |
Ripple |
<0.05% RMS of rated voltage at full load |
1.8 |
Stability |
< 0.01%/hour after 1 hour warm up |
1.9 |
Regulating Mode |
Constant Voltage/Constant Current. |
1.10 |
Voltage &Current Control |
By external 10 turn potentiometers with lockable counting dials. |
1.11 |
Protections |
Against overload, over voltage, short- circuit and arc:
During short circuit, power supply trips and it is to be manually reset to restart . |
1.12 |
Front Panel ** |
AC Power ON/OFF switch with indication
HV ON/OFF switch with indication
3½ digit voltage and current meters
10 turn potentiometers for voltage and current meters
10 turn potentiometers for voltage and current control.Constant voltage, constant current mode indication |
1.13 |
Back Panel |
AC power input connector with fuse, HV output connector and ground stud |
1.14 |
Topology |
High frequency switch mode |